Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Power loss16W
Concurrently switching neutral conductorNo
Release characteristicB
Rated short-circuit breaking capacity according to IEC 60947-210kA
Disconnection characteristicUndelayed
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to EN 610096kA
Voltage typeAC
Pollution degree2
Number of protected poles2
Rated current16A
Rated insulation voltage Ui500V
Rated fault current0.3A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Leakage current typeA
Current limiting class3
With interlocking deviceNo
Frequency50/60 Hz
Over voltage category3
Flush-mounted installationNo
Built-in depth72mm
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95137 | Compact RCBO 2P B16 6KA A/0,3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Power loss

16W

Concurrently switching neutral conductor

Release characteristic

B

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Voltage type

AC

Pollution degree

2

Number of protected poles

2

Rated current

16A

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Leakage current type

A

Current limiting class

3

With interlocking device

Frequency

50/60 Hz

Over voltage category

3

Flush-mounted installation

Built-in depth

72mm

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.