Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui500V
Built-in depth72mm
Surge current capacity0.25kA
Leakage current typeA
Current limiting class1
Pollution degree2
Rated voltage400V
Rated fault current0.03A
Over voltage category3
Rated current3.18A
Release characteristicB
Voltage typeAC
Width in number of modular spacings3
Power loss6W
Frequency50/60 Hz
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Number of protected poles3
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Number of poles (total)3
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95145

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Built-in depth

72mm

Surge current capacity

0.25kA

Leakage current type

A

Current limiting class

1

Pollution degree

2

Rated voltage

400V

Rated fault current

0.03A

Over voltage category

3

Rated current

3.18A

Release characteristic

B

Voltage type

AC

Width in number of modular spacings

3

Power loss

6W

Frequency

50/60 Hz

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Number of protected poles

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Flush-mounted installation

Number of poles (total)

3

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.