Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)3
Rated voltage400V
Rated current16A
Rated fault current0.03A
Rated short-circuit breaking capacity according to EN 610096kA
Power loss16W
Leakage current typeA
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to IEC 60947-26kA
Current limiting class1
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Concurrently switching neutral conductorNo
Voltage typeAC
With interlocking deviceNo
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Pollution degree2
Rated insulation voltage Ui500V
Release characteristicB
Ambient temperature during operating-25 - 40°C
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Frequency50/60 Hz
Width in number of modular spacings3
Over voltage category3
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95147 | Compact RCBO 3P B16 6KA A/0,03 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

3

Rated voltage

400V

Rated current

16A

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

6kA

Power loss

16W

Leakage current type

A

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Current limiting class

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Concurrently switching neutral conductor

Voltage type

AC

With interlocking device

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Pollution degree

2

Rated insulation voltage Ui

500V

Release characteristic

B

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Frequency

50/60 Hz

Width in number of modular spacings

3

Over voltage category

3

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.