Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Anti-nuisance tripping versionNo
Surge current capacity0.25kA
Degree of protection (IP)IP20
Frequency50/60 Hz
Release characteristicB
With interlocking deviceNo
Rated current10A
Rated fault current0.3A
Leakage current typeA
Width in number of modular spacings3
Current limiting class1
Concurrently switching neutral conductorNo
Pollution degree2
Power loss10W
Rated voltage400V
Rated insulation voltage Ui500V
Ambient temperature during operating-25 - 40°C
Number of poles (total)3
Over voltage category3
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95156

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Anti-nuisance tripping version

Surge current capacity

0.25kA

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Release characteristic

B

With interlocking device

Rated current

10A

Rated fault current

0.3A

Leakage current type

A

Width in number of modular spacings

3

Current limiting class

1

Concurrently switching neutral conductor

Pollution degree

2

Power loss

10W

Rated voltage

400V

Rated insulation voltage Ui

500V

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

3

Over voltage category

3

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.