Technical specifications

Voltage typeAC
Rated voltage400V
Frequency50/60 Hz
Rated current11.01A
Over voltage category3
Power loss32W
Pollution degree2
Rated insulation voltage Ui500V
Release characteristicB
Built-in depth72mm
Number of protected poles3
Degree of protection (IP)IP20
Surge current capacity0.25kA
Current limiting class1
Leakage current typeA
Rated fault current0.3A
Width in number of modular spacings3
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
With interlocking deviceNo
Number of poles (total)3
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95160

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated voltage

400V

Frequency

50/60 Hz

Rated current

11.01A

Over voltage category

3

Power loss

32W

Pollution degree

2

Rated insulation voltage Ui

500V

Release characteristic

B

Built-in depth

72mm

Number of protected poles

3

Degree of protection (IP)

IP20

Surge current capacity

0.25kA

Current limiting class

1

Leakage current type

A

Rated fault current

0.3A

Width in number of modular spacings

3

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

With interlocking device

Number of poles (total)

3

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.