Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles4
Rated insulation voltage Ui500V
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Rated fault current0.03A
Leakage current typeA
Rated current32A
Rated short-circuit breaking capacity according to EN 610096kA
Current limiting class1
Power loss32W
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Voltage typeAC
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Surge current capacity0.25kA
Release characteristicB
Pollution degree2
Over voltage category3
Width in number of modular spacings4
Built-in depth72mm
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95170 | Compact RCBO 4P B32 6KA A/0,03 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

4

Rated insulation voltage Ui

500V

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Rated fault current

0.03A

Leakage current type

A

Rated current

32A

Rated short-circuit breaking capacity according to EN 61009

6kA

Current limiting class

1

Power loss

32W

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Voltage type

AC

Frequency

50/60 Hz

Concurrently switching neutral conductor

Surge current capacity

0.25kA

Release characteristic

B

Pollution degree

2

Over voltage category

3

Width in number of modular spacings

4

Built-in depth

72mm

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.