Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category3
Leakage current typeA
Degree of protection (IP)IP20
Built-in depth72mm
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Surge current capacity0.25kA
Release characteristicB
Number of protected poles4
Frequency50/60 Hz
Voltage typeAC
Power loss16W
Current limiting class1
Rated voltage400V
Pollution degree2
Rated fault current0.3A
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated insulation voltage Ui500V
Rated current9.12A
Connectable conductor cross section solid-core35 - 35mm²
With interlocking deviceNo
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Number of poles (total)4
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95177

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Over voltage category

3

Leakage current type

A

Degree of protection (IP)

IP20

Built-in depth

72mm

Width in number of modular spacings

4

Concurrently switching neutral conductor

Surge current capacity

0.25kA

Release characteristic

B

Number of protected poles

4

Frequency

50/60 Hz

Voltage type

AC

Power loss

16W

Current limiting class

1

Rated voltage

400V

Pollution degree

2

Rated fault current

0.3A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated insulation voltage Ui

500V

Rated current

9.12A

Connectable conductor cross section solid-core

35 .. 35mm²

With interlocking device

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Number of poles (total)

4

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.