Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)4
Number of protected poles4
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current32A
Rated fault current0.3A
Leakage current typeA
Current limiting class1
Rated short-circuit breaking capacity according to IEC 60947-26kA
Power loss32W
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Concurrently switching neutral conductorNo
Surge current capacity0.25kA
With interlocking deviceNo
Frequency50/60 Hz
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Voltage typeAC
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 40°C
Release characteristicB
Width in number of modular spacings4
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Built-in depth72mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95180 | Compact RCBO 4P B32 6KA A/0,3 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

4

Number of protected poles

4

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Rated fault current

0.3A

Leakage current type

A

Current limiting class

1

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Power loss

32W

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Concurrently switching neutral conductor

Surge current capacity

0.25kA

With interlocking device

Frequency

50/60 Hz

Flush-mounted installation

Anti-nuisance tripping version

Voltage type

AC

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Release characteristic

B

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Built-in depth

72mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.