Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Current limiting class3
Voltage typeAC
Rated fault current0.03A
Over voltage category3
Built-in depth72mm
Leakage current typeA
Rated insulation voltage Ui500V
Release characteristicB
Width in number of modular spacings2
Pollution degree2
Degree of protection (IP)IP20
Frequency50/60 Hz
Number of protected poles2
Surge current capacity0.25kA
Rated voltage230V
Rated current4.56A
Concurrently switching neutral conductorNo
Power loss16W
Rated short-circuit breaking capacity according to IEC 60947-215kA
Connectable conductor cross section solid-core35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
With interlocking deviceNo
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95327

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Current limiting class

3

Voltage type

AC

Rated fault current

0.03A

Over voltage category

3

Built-in depth

72mm

Leakage current type

A

Rated insulation voltage Ui

500V

Release characteristic

B

Width in number of modular spacings

2

Pollution degree

2

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Number of protected poles

2

Surge current capacity

0.25kA

Rated voltage

230V

Rated current

4.56A

Concurrently switching neutral conductor

Power loss

16W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Connectable conductor cross section solid-core

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

With interlocking device

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.