Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Built-in depth72mm
Pollution degree2
Release characteristicB
Rated current5.44A
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-215kA
Width in number of modular spacings2
Power loss20W
Surge current capacity0.25kA
Frequency50/60 Hz
Over voltage category3
Rated fault current0.1A
Number of protected poles2
Current limiting class3
Rated voltage230V
With interlocking deviceNo
Number of poles (total)2
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Leakage current typeA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95798

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Built-in depth

72mm

Pollution degree

2

Release characteristic

B

Rated current

5.44A

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Width in number of modular spacings

2

Power loss

20W

Surge current capacity

0.25kA

Frequency

50/60 Hz

Over voltage category

3

Rated fault current

0.1A

Number of protected poles

2

Current limiting class

3

Rated voltage

230V

With interlocking device

Number of poles (total)

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Anti-nuisance tripping version

Leakage current type

A

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.