Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Rated insulation voltage Ui500V
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated fault current0.1A
Rated current20A
Leakage current typeA
Current limiting class3
Power loss20W
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to EN 6100910kA
Voltage typeAC
Release characteristicB
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Built-in depth72mm
With interlocking deviceNo
Over voltage category3
Pollution degree2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95798 | Compact RCBO 2P B20 10KA A/0,1 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Rated insulation voltage Ui

500V

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.1A

Rated current

20A

Leakage current type

A

Current limiting class

3

Power loss

20W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Voltage type

AC

Release characteristic

B

Frequency

50/60 Hz

Concurrently switching neutral conductor

Anti-nuisance tripping version

Built-in depth

72mm

With interlocking device

Over voltage category

3

Pollution degree

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.