Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Frequency50/60 Hz
Rated insulation voltage Ui500V
Rated current25A
Over voltage category3
Surge current capacity0.25kA
Leakage current typeA
Current limiting class3
Rated fault current0.1A
Power loss25W
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated voltage230V
Pollution degree2
Built-in depth72mm
Release characteristicB
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Number of protected poles2
Flush-mounted installationNo
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Concurrently switching neutral conductorNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95799

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Frequency

50/60 Hz

Rated insulation voltage Ui

500V

Rated current

25A

Over voltage category

3

Surge current capacity

0.25kA

Leakage current type

A

Current limiting class

3

Rated fault current

0.1A

Power loss

25W

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated voltage

230V

Pollution degree

2

Built-in depth

72mm

Release characteristic

B

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Number of protected poles

2

Flush-mounted installation

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Concurrently switching neutral conductor

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.