  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles2
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current6A
Rated fault current0.3A
Current limiting class3
Power loss6W
Leakage current typeA
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Concurrently switching neutral conductorNo
Release characteristicB
With interlocking deviceNo
Frequency50/60 Hz
Over voltage category3
Degree of protection (IP)IP20
Pollution degree2
Width in number of modular spacings2
Built-in depth72mm
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95335 | Compact RCBO 2P B6 10KA A/0,3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

6A

Rated fault current

0.3A

Current limiting class

3

Power loss

6W

Leakage current type

A

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Concurrently switching neutral conductor

Release characteristic

B

With interlocking device

Frequency

50/60 Hz

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

2

Width in number of modular spacings

2

Built-in depth

72mm

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²