Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles2
Rated insulation voltage Ui500V
Rated current10A
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Leakage current typeA
Power loss10W
Rated short-circuit breaking capacity according to IEC 60947-215kA
Width in number of modular spacings2
Frequency50/60 Hz
With interlocking deviceNo
Pollution degree2
Rated short-circuit breaking capacity according to EN 6100910kA
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicShort-time delayed
Current limiting class3
Surge current capacity3kA
Voltage typeAC
Concurrently switching neutral conductorNo
Release characteristicB
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95836 | Compact RCBO 2P B10 10KA AIR/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated current

10A

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Leakage current type

A

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Width in number of modular spacings

2

Frequency

50/60 Hz

With interlocking device

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Short-time delayed

Current limiting class

3

Surge current capacity

3kA

Voltage type

AC

Concurrently switching neutral conductor

Release characteristic

B

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.