Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated current4.56A
Voltage typeAC
Release characteristicB
Rated voltage230V
Rated insulation voltage Ui500V
Surge current capacity3kA
Number of protected poles2
Pollution degree2
Current limiting class3
Leakage current typeA
Connectable conductor cross section solid-core35 - 35mm²
Over voltage category3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Concurrently switching neutral conductorNo
Rated fault current0.03A
Frequency50/60 Hz
Power loss16W
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity according to EN 6100910kA
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
Anti-nuisance tripping versionYes
Number of poles (total)2
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95837

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated current

4.56A

Voltage type

AC

Release characteristic

B

Rated voltage

230V

Rated insulation voltage Ui

500V

Surge current capacity

3kA

Number of protected poles

2

Pollution degree

2

Current limiting class

3

Leakage current type

A

Connectable conductor cross section solid-core

35 .. 35mm²

Over voltage category

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Concurrently switching neutral conductor

Rated fault current

0.03A

Frequency

50/60 Hz

Power loss

16W

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity according to EN 61009

10kA

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

Anti-nuisance tripping version

Number of poles (total)

2

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.