  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current5.44A
Built-in depth72mm
Voltage typeAC
Rated insulation voltage Ui500V
Rated fault current0.03A
Leakage current typeA
Surge current capacity3kA
Release characteristicB
Frequency50/60 Hz
Power loss20W
Over voltage category3
Degree of protection (IP)IP20
Number of protected poles2
Current limiting class3
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Pollution degree2
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
With interlocking deviceNo
Anti-nuisance tripping versionYes
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95838

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

5.44A

Built-in depth

72mm

Voltage type

AC

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Leakage current type

A

Surge current capacity

3kA

Release characteristic

B

Frequency

50/60 Hz

Power loss

20W

Over voltage category

3

Degree of protection (IP)

IP20

Number of protected poles

2

Current limiting class

3

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

2

Concurrently switching neutral conductor

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

With interlocking device

Anti-nuisance tripping version

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity according to EN 61009

10kA