Number of poles (total)2
Number of protected poles2
Rated insulation voltage Ui500V
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current13A
Current limiting class3
Leakage current typeA
Power loss13W
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity according to EN 6100910kA
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicShort-time delayed
Surge current capacity3kA
Release characteristicB
Over voltage category3
Concurrently switching neutral conductorNo
Frequency50/60 Hz
With interlocking deviceNo
Pollution degree2
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Width in number of modular spacings2
Degree of protection (IP)IP20
Built-in depth72mm
Anti-nuisance tripping versionYes
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95841 | Compact RCBO 2P B13 10KA AIR/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

13A

Current limiting class

3

Leakage current type

A

Power loss

13W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Short-time delayed

Surge current capacity

3kA

Release characteristic

B

Over voltage category

3

Concurrently switching neutral conductor

Frequency

50/60 Hz

With interlocking device

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Built-in depth

72mm

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²