Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu125A
Overload release current setting50 - 125A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release50 - 125A
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
With switched-off indicatorYes
Type of control elementRocker lever
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Number of poles4
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9316

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

125A

Overload release current setting

50 .. 125A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

50 .. 125A

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

With switched-off indicator

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Number of poles

4

Complete device with protection unit

Motor drive integrated

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.