Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu125A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Type of control elementRocker lever
With switched-off indicatorYes
Motor drive integratedNo
Number of poles4
With integrated under voltage releaseNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release50 - 125A
Overload release current setting50 - 125A
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9326

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

125A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Type of control element

Rocker lever

With switched-off indicator

Motor drive integrated

Number of poles

4

With integrated under voltage release

Complete device with protection unit

Degree of protection (IP)

IP20

Integrated earth fault protection

Motor drive optional

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

50 .. 125A

Overload release current setting

50 .. 125A

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.