Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu160A
Device constructionBuilt-in device fixed built-in technique
Overload release current setting64 - 160A
Adjustment range short-term delayed short-circuit release64 - 160A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Type of control elementRocker lever
Number of poles4
Degree of protection (IP)IP20
Motor drive optionalYes
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9327

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

160A

Device construction

Built-in device fixed built-in technique

Overload release current setting

64 .. 160A

Adjustment range short-term delayed short-circuit release

64 .. 160A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

With integrated under voltage release

Motor drive integrated

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Type of control element

Rocker lever

Number of poles

4

Degree of protection (IP)

IP20

Motor drive optional

With switched-off indicator

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.