Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu160A
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release64 - 160A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
Overload release current setting64 - 160A
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorYes
Type of control elementRocker lever
Motor drive optionalYes
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Number of poles4
Degree of protection (IP)IP20
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9357

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

160A

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

64 .. 160A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

64 .. 160A

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Type of control element

Rocker lever

Motor drive optional

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive integrated

Number of poles

4

Degree of protection (IP)

IP20

With integrated under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.