  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu250A
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release100 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorYes
Overload release current setting100 - 250A
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Motor drive integratedNo
Type of control elementRocker lever
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Complete device with protection unitYes
Number of poles4
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9358

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

250A

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

100 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Overload release current setting

100 .. 250A

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Motor drive integrated

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Complete device with protection unit

Number of poles

4

With integrated under voltage release