Rated permanent current Iu630A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Motor drive integratedNo
Number of poles4
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release252 - 630A
With switched-off indicatorYes
Motor drive optionalYes
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Position of connection for main current circuitFront side
Overload release current setting252 - 630A
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalNo
With integrated under voltage releaseNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9383

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

630A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Motor drive integrated

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

252 .. 630A

With switched-off indicator

Motor drive optional

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Position of connection for main current circuit

Front side

Overload release current setting

252 .. 630A

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.