Technical specifications

Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release252 - 630A
Rated permanent current Iu630A
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Overload release current setting252 - 630A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
DIN rail (top hat rail) mounting optionalNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Number of poles4
Type of control elementRocker lever
Degree of protection (IP)IP20
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9384

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

252 .. 630A

Rated permanent current Iu

630A

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Overload release current setting

252 .. 630A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Motor drive integrated

Motor drive optional

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique