Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Overload release current setting320 - 800A
Rated permanent current Iu800A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release320 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Motor drive optionalYes
Number of poles4
Complete device with protection unitYes
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Type of control elementRocker lever
With switched-off indicatorYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9403

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Overload release current setting

320 .. 800A

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

320 .. 800A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Motor drive optional

Number of poles

4

Complete device with protection unit

Position of connection for main current circuit

Front side

With integrated under voltage release

Type of control element

Rocker lever

With switched-off indicator

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.