Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Degree of protection (IP)IP20
Type of control elementRocker lever
Number of poles3
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu1250A
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Motor drive integratedNo
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Overload release current setting500 - 1250A
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1875 - 15000A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release1250 - 12500A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW97604

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

1250A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Motor drive integrated

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Overload release current setting

500 .. 1250A

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1875 .. 15000A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range short-term delayed short-circuit release

1250 .. 12500A

Position of connection for main current circuit

Front side

Integrated earth fault protection

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

With under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.