Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Integrated earth fault protectionNo
Rated permanent current Iu1250A
Adjustment range short-term delayed short-circuit release500 - 1250A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
With switched-off indicatorYes
Position of connection for main current circuitFront side
Number of poles3
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Overload release current setting500 - 1250A
Type of control elementRocker lever
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9411B

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Integrated earth fault protection

Rated permanent current Iu

1250A

Adjustment range short-term delayed short-circuit release

500 .. 1250A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Position of connection for main current circuit

Front side

Number of poles

3

Motor drive optional

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Overload release current setting

500 .. 1250A

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.