Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu1600A
Rated voltage690 - 690V
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release640 - 1600A
Number of auxiliary contacts as normally open contact0
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Motor drive optionalYes
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Overload release current setting640 - 1600A
Number of poles4
Motor drive integratedNo
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9425

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

1600A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

640 .. 1600A

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Motor drive optional

With integrated under voltage release

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Overload release current setting

640 .. 1600A

Number of poles

4

Motor drive integrated

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.