Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu1600A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release640 - 1600A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally open contact0
Overload release current setting640 - 1600A
With switched-off indicatorYes
Motor drive integratedNo
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
DIN rail (top hat rail) mounting optionalNo
Number of poles4
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GWD9427B

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

1600A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

640 .. 1600A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally open contact

0

Overload release current setting

640 .. 1600A

With switched-off indicator

Motor drive integrated

With integrated under voltage release

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

DIN rail (top hat rail) mounting optional

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.