Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Degree of protection (IP)IP20
Type of control elementRocker lever
Number of poles4
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu1000A
Overload release current setting400 - 1000A
Motor drive optionalYes
Rated voltage690 - 690V
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Adjustment range undelayed short-circuit release1500 - 12000A
Adjustment range short-term delayed short-circuit release600 - 10000A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
With switched-off indicatorYes
Integrated earth fault protectionNo
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DX10025R

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

1000A

Overload release current setting

400 .. 1000A

Motor drive optional

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Adjustment range undelayed short-circuit release

1500 .. 12000A

Adjustment range short-term delayed short-circuit release

600 .. 10000A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

With switched-off indicator

Integrated earth fault protection

With under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.