  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Adjustment range short-term delayed short-circuit release50 - 125A
Overload release current setting50 - 125A
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalYes
Rated permanent current Iu125A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Type of control elementRocker lever
Motor drive integratedNo
Complete device with protection unitYes
Number of poles4
Motor drive optionalYes
With switched-off indicatorYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53523

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Adjustment range short-term delayed short-circuit release

50 .. 125A

Overload release current setting

50 .. 125A

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Rated permanent current Iu

125A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Type of control element

Rocker lever

Motor drive integrated

Complete device with protection unit

Number of poles

4

Motor drive optional

With switched-off indicator

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20