Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu160A
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release64 - 160A
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Type of control elementRocker lever
Number of poles4
With switched-off indicatorYes
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
Overload release current setting64 - 160A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53525

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

160A

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

64 .. 160A

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Type of control element

Rocker lever

Number of poles

4

With switched-off indicator

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

With integrated under voltage release

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Overload release current setting

64 .. 160A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.