Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of electrical connection of main circuitBolt connection
Rated voltage690 - 690V
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Overload release current setting160 - 400A
Complete device with protection unitYes
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release160 - 400A
With switched-off indicatorYes
Number of poles4
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53538

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of electrical connection of main circuit

Bolt connection

Rated voltage

690 .. 690V

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Overload release current setting

160 .. 400A

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

160 .. 400A

With switched-off indicator

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.