Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu1250A
Device constructionBuilt-in device fixed built-in technique
Overload release current setting500 - 1250A
Integrated earth fault protectionNo
Number of poles4
Type of electrical connection of main circuitBolt connection
With switched-off indicatorYes
Rated voltage690 - 690V
Type of control elementRocker lever
Complete device with protection unitYes
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release500 - 1250A
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Position of connection for main current circuitFront side
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53734

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

1250A

Device construction

Built-in device fixed built-in technique

Overload release current setting

500 .. 1250A

Integrated earth fault protection

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Rated voltage

690 .. 690V

Type of control element

Rocker lever

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

500 .. 1250A

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Position of connection for main current circuit

Front side

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.