Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Overload release current setting100 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Adjustment range short-term delayed short-circuit release100 - 250A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
With switched-off indicatorYes
Number of poles3
Type of control elementRocker lever
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53446

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Overload release current setting

100 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Adjustment range short-term delayed short-circuit release

100 .. 250A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

With switched-off indicator

Number of poles

3

Type of control element

Rocker lever

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

Complete device with protection unit