Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu1600A
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Number of poles3
With integrated under voltage releaseNo
Overload release current setting640 - 1600A
Adjustment range short-term delayed short-circuit release640 - 1600A
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
With switched-off indicatorYes
Type of control elementRocker lever
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53743

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

1600A

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Number of poles

3

With integrated under voltage release

Overload release current setting

640 .. 1600A

Adjustment range short-term delayed short-circuit release

640 .. 1600A

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

With switched-off indicator

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.