Rated permanent current Iu630A
Overload release current setting252 - 630A
Adjustment range short-term delayed short-circuit release252 - 630A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorYes
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of poles4
Complete device with protection unitYes
Motor drive integratedNo
Type of control elementRocker lever
Rated voltage690 - 690V
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV53620

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated permanent current Iu

630A

Overload release current setting

252 .. 630A

Adjustment range short-term delayed short-circuit release

252 .. 630A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of poles

4

Complete device with protection unit

Motor drive integrated

Type of control element

Rocker lever

Rated voltage

690 .. 690V

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Degree of protection (IP)

IP20