  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu1600A
Overload release current setting640 - 1600A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Degree of protection (IP)IP20
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
With switched-off indicatorYes
DIN rail (top hat rail) mounting optionalNo
Number of poles4
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release640 - 1600A
Number of auxiliary contacts as normally open contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MV64261

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

1600A

Overload release current setting

640 .. 1600A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

Complete device with protection unit

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

With switched-off indicator

DIN rail (top hat rail) mounting optional

Number of poles

4

Motor drive integrated

Adjustment range short-term delayed short-circuit release

640 .. 1600A

Number of auxiliary contacts as normally open contact

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.