Type of control gearLED operating device current-controlled
Conductor cross section1.5mm²
Connection typePush-in clamp
Lamp typeLED not exchangeable
Colour rendering index CRI80-89
Material reflectorPlastic
Nominal voltage220 - 240V
Emergency power supply integratedYes
Luminaire with limited surface temperature, sign "D“Yes
Suitable for emergency lightingYes
Nominal current330 - 330mA
Beam angleWide beam 41-80°
Constant light output (CLO)No
Suitable for number of lamps1
Rated luminous flux according to IEC 62722-2-19500lm
Rated ambient temperature according to IEC62722-2-10 - 40°C
Filament test according to IEC 60695-2-11850 °C - 30 s
Colour consistency (McAdam ellipse)SDCM3
Photobiological safety according to EN 62471RG0
Dimming potentiometer (integrated)No
Dimming mains voltage modulationNo
Suitable for auxiliary lampNo
Dimming Sine Wave ReductionNo
Dimming with push-buttonNo
Dimming manufacturer's proprietary systemNo
Light distributorRefractor lens
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)90%
Max. number of luminaires per miniature circuit breaker C1617
Max. number of luminaires per miniature circuit breaker B1610
Luminaire efficacy148lm/W
Exchangeable control gearYes
Colour temperature adjustableNo
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)10%
Luminous flux adjustableContinuously variable
Degree of protection (IP)IP65
Colour temperature3000 - 3000K