Conductor cross section1.5mm²
Connection typePush-in clamp
Type of control gearLED operating device current-controlled
Colour rendering index CRI80-89
Emergency power supply integratedNo
Suitable for number of lamps3
Suitable for emergency lightingNo
Beam angleExtreme wide beam >80°
Material housingAluminium
Lamp typeLED not exchangeable
Nominal current600 - 600mA
Nominal voltage220 - 240V
Luminaire with limited surface temperature, sign "D“No
Material reflectorWithout reflector
Constant light output (CLO)No
Rated luminous flux according to IEC 62722-2-16700lm
Photobiological safety according to EN 62471RG0
Dimming Sine Wave ReductionNo
Dimming manufacturer's proprietary systemNo
Filament test according to IEC 60695-2-11650 °C - 30 s
Colour consistency (McAdam ellipse)SDCM3
Dimming mains voltage modulationNo
Rated ambient temperature according to IEC62722-2-1-25 - 50°C
Dimming potentiometer (integrated)No
Dimming with push-buttonNo
Light distributorFocal lens
Luminaire efficacy129lm/W
Max. number of luminaires per miniature circuit breaker C1617
Luminous flux adjustableContinuously variable
Exchangeable control gearYes
Colour temperature adjustableNo
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)90%
Max. number of luminaires per miniature circuit breaker B1610
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)10%
Suitable for auxiliary lampNo
Degree of protection (IP)IP65
Colour temperature4000 - 4000K