Suitable for emergency lightingYes
Connection typePush-in clamp
Conductor cross section1.5mm²
Type of control gearLED operating device current-controlled
Colour rendering index CRI80-89
Material housingAluminium
Lamp typeLED not exchangeable
Light sharingSymmetric/asymmetric
Beam angleWide beam 41-80°
Nominal voltage220 - 240V
Material reflectorWithout reflector
Luminaire with limited surface temperature, sign "D“No
Filament test according to IEC 60695-2-11650 °C - 30 s
Photobiological safety according to EN 62471RG0
Rated luminous flux according to IEC 62722-2-16700lm
Emergency power supply integratedYes
Rated ambient temperature according to IEC62722-2-10 - 40°C
Suitable for number of lamps6
Colour consistency (McAdam ellipse)SDCM3
Nominal current600 - 600mA
Constant light output (CLO)No
Dimming mains voltage modulationNo
Dimming potentiometer (integrated)No
Dimming Sine Wave ReductionNo
Dimming manufacturer's proprietary systemNo
Dimming with push-buttonNo
Max. number of luminaires per miniature circuit breaker C1617
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)10%
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)90%
Luminous flux adjustableContinuously variable
Max. number of luminaires per miniature circuit breaker B1610
Light distributorFocal lens
Luminaire efficacy129lm/W
Colour temperature adjustableNo
Suitable for auxiliary lampYes
Exchangeable control gearYes
Degree of protection (IP)IP55
Colour temperature4000 - 4000K