Details
- •Luminaires
- •High bay luminaire
- •1 KOM
- •GEWISS
Technical specifications
GWS6084GD30K

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Luminaires
- High bay luminaire
- 1 KOM
- GEWISS
Technical specifications
Mounting method
Pendant
Reflector
None
Width
536mm
Protection class
I
Type of control gear
LED operating device current-controlled
Connection type
Push-in clamp
Lamp holder
None
Voltage type
AC
Colour housing
Grey
Conductor cross section
1.5mm²
Colour rendering index CRI
80-89
Ball-proof
Number of poles
5
Length
979mm
Height/depth
176mm
Suitable for emergency lighting
Lamp type
LED not exchangeable
Impact strength
IK07
Degree of protection (IP)
IP65
Emergency power supply integrated
With light source
Light sharing
Symmetric
Material reflector
Without reflector
With protective cover
Luminaire with limited surface temperature, sign "D“
Material housing
Aluminium
Nominal voltage
220 .. 240V
Beam angle
Medium beam 21-40°
Colour of light
White
Suitable for number of lamps
6
Max. system power
420W
Rated luminous flux according to IEC 62722-2-1
47700lm
Colour temperature
3000 .. 3000K
With control gear
Nominal current
900 .. 900mA
Dimming potentiometer (integrated)
Dimming phase cut-on
Dimming 1-10 V
Dimming phase cut-off
Filament test according to IEC 60695-2-11
650 °C - 30 s
Dimming RF
Rated ambient temperature according to IEC62722-2-1
-25 .. 50°C
Dimming mains voltage modulation
Dimming DMX
Photobiological safety according to EN 62471
RG0
Dimming 0-10 V
Colour consistency (McAdam ellipse)
SDCM3
Dimming Sine Wave Reduction
Dimming LineSwitch
Dimming manufacturer's proprietary system
Dimming programmable
Type of wiring
Ending
Dimming DALI
Constant light output (CLO)
Dimming Touch and Dim
Luminaire efficacy
114lm/W
No dim function
Dimming Zigbee
Light distributor
Focal lens
Dimming with push-button
Dimming DSI
Max. number of luminaires per miniature circuit breaker B16
2
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)
10%
Beam angle adjustable
No
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)
90%
Operation by Bluetooth
Exchangeable control gear
Luminous flux adjustable
Continuously variable
Colour temperature adjustable
No
Suitable for auxiliary lamp
Power factor
0.9
Max. number of luminaires per miniature circuit breaker C16
3