Technical specifications

Overload release current setting44.1 - 63A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP40
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingYes
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release800 - 800A
Motor drive optionalNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Rated permanent current Iu63A
Number of poles3
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

C11E3TM063B | Prekidač NSXM100E 16KA 3P 63A TMD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

44.1 .. 63A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP40

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Adjustment range undelayed short-circuit release

800 .. 800A

Motor drive optional

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Rated permanent current Iu

63A

Number of poles

3

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

16kA