  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Mounting methodDIN rail
Height48mm
InterfaceNo
Width45mm
Depth56mm
Number of auxiliary contacts as normally open contact1
Suitable for manual operationNo
Rated switch current6A
Rated operation current Ie, 400 V4A
Connection type auxiliary circuitScrew connection
Rated control supply voltage Us at AC 50HZ208 - 220V
Rated control supply voltage Us at AC 60HZ208 - 220V
Number of auxiliary contacts as normally closed contact3
Rated control supply voltage Us at DC- - -V
With LED indicationNo
Number of auxiliary contacts as change-over contact0
Voltage type (operating voltage)AC
Number of auxiliary contacts as normally open contact, leading0
Operating voltage at AC 50 Hz690 - 690V
Operating voltage at DC440 - 440V
Rated operation current6A
Voltage type for actuatingAC
Operating voltage at AC 60 Hz690 - 690V
Number of auxiliary contacts as normally closed contact, delayed switching0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SAH220417R9900 | MCRA013ATM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN rail

Height

48mm

Interface

Width

45mm

Depth

56mm

Number of auxiliary contacts as normally open contact

1

Suitable for manual operation

Rated switch current

6A

Rated operation current Ie, 400 V

4A

Connection type auxiliary circuit

Screw connection

Rated control supply voltage Us at AC 50HZ

208 .. 220V

Rated control supply voltage Us at AC 60HZ

208 .. 220V

Number of auxiliary contacts as normally closed contact

3

Rated control supply voltage Us at DC

- .. -V

With LED indication

Number of auxiliary contacts as change-over contact

0

Voltage type (operating voltage)

AC

Number of auxiliary contacts as normally open contact, leading

0

Operating voltage at AC 50 Hz

690 .. 690V

Operating voltage at DC

440 .. 440V

Rated operation current

6A

Voltage type for actuating

AC

Operating voltage at AC 60 Hz

690 .. 690V

Number of auxiliary contacts as normally closed contact, delayed switching

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.