Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as emergency stop installation
No
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Rated permanent current at AC-23, 400 V
400A
Rated permanent current Iu
500A
Max. rated operation voltage Ue AC
1000V
Rated operating voltage
1000 - 1000V
Rated permanent current at AC-21, 400 V
500A
Version as reversing switch
No
Rated short-time withstand current lcw
15kA
Rated operation power at AC-3, 400 V
-kW
Number of switches
1
Rated operation power at AC-23, 400 V
132kW
Conditioned rated short-circuit current Iq
-kA
Switching power at 400 V
132kW
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Device construction
Complete device in housing
Voltage release optional
No
Suitable for front mounting 4-hole
No
Suitable for floor mounting
No
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Interlockable
No
Suitable for intermediate mounting
No
Degree of protection (NEMA)
Other
With pre-assembled cabling
No
Degree of protection (IP), front side
IP00
Type of control element
Other
Type of electrical connection of main circuit
Bolt connection
Width
196mm
Height
185mm
Width in number of modular spacings
-
Depth
107mm
1SCA101319R1001 | OT500E12

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as emergency stop installation
Version as main switch
Version as maintenance-/service switch
Version as safety switch
Rated permanent current at AC-23, 400 V
400A
Rated permanent current Iu
500A
Max. rated operation voltage Ue AC
1000V
Rated operating voltage
1000 .. 1000V
Rated permanent current at AC-21, 400 V
500A
Version as reversing switch
Rated short-time withstand current lcw
15kA
Rated operation power at AC-3, 400 V
-kW
Number of switches
1
Rated operation power at AC-23, 400 V
132kW
Conditioned rated short-circuit current Iq
-kA
Switching power at 400 V
132kW
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Device construction
Complete device in housing
Voltage release optional
Suitable for front mounting 4-hole
Suitable for floor mounting
Suitable for front mounting centre
Suitable for distribution board installation
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Interlockable
Suitable for intermediate mounting
Degree of protection (NEMA)
Other
With pre-assembled cabling
Degree of protection (IP), front side
IP00
Type of control element
Other
Type of electrical connection of main circuit
Bolt connection
Width
196mm
Height
185mm
Width in number of modular spacings
-
Depth
107mm
We use cookies to enhance your experience.