Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Overload release current setting25 - 25A
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Motor drive integratedNo
Adjustment range undelayed short-circuit release500 - 500A
With switched-off indicatorNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Rated permanent current Iu125A
Number of poles4
Rated voltage240 - 347V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz35kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA074681R1 | XT1S 125 TMF 25-500 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Overload release current setting

25 .. 25A

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Position of connection for main current circuit

Front side

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive integrated

Adjustment range undelayed short-circuit release

500 .. 500A

With switched-off indicator

With under voltage release

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Rated permanent current Iu

125A

Number of poles

4

Rated voltage

240 .. 347V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

35kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.