Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Overload release current setting70.0 - 100A
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release- - -A
Adjustment range undelayed short-circuit release500 - 1000A
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorNo
Type of control elementToggle
Complete device with protection unitYes
Rated permanent current Iu125A
Number of poles3
Rated voltage240 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA074744R1 | XT2N 125 TMA 100-500..1000 3p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Overload release current setting

70.0 .. 100A

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Adjustment range undelayed short-circuit release

500 .. 1000A

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Type of control element

Toggle

Complete device with protection unit

Rated permanent current Iu

125A

Number of poles

3

Rated voltage

240 .. 600V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.