Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Number of poles3
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu125A
Degree of protection (IP)IP20
Overload release current setting4.0 - 10A
Rated voltage240 - 600V
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release10 - 100A
Motor drive optionalYes
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release10 - 100A
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA074940R1 | XT2V 125 Ekip LS/I In=10A 3p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

125A

Degree of protection (IP)

IP20

Overload release current setting

4.0 .. 10A

Rated voltage

240 .. 600V

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

10 .. 100A

Motor drive optional

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

10 .. 100A

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

With under voltage release

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.