Technical specifications

Rated voltage240 - 600V
Overload release current setting4.0 - 10A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Rated permanent current Iu125A
Position of connection for main current circuitFront side
Number of poles4
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release10 - 100A
Motor drive integratedNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release10 - 100A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075005R1 | XT2N 125 Ekip LSIG In=10A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240 .. 600V

Overload release current setting

4.0 .. 10A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Rated permanent current Iu

125A

Position of connection for main current circuit

Front side

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

10 .. 100A

Motor drive integrated

With switched-off indicator

Adjustment range short-term delayed short-circuit release

10 .. 100A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Motor drive optional

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.