Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of poles4
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Overload release current setting10.0 - 25A
Position of connection for main current circuitFront side
Type of control elementToggle
Rated permanent current Iu125A
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Rated voltage240 - 600V
Adjustment range short-term delayed short-circuit release25 - 250A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release25 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz35kA
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA075016R1 | XT2S 125 Ekip LSIG In=25A 4p F F UL/CSA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Overload release current setting

10.0 .. 25A

Position of connection for main current circuit

Front side

Type of control element

Toggle

Rated permanent current Iu

125A

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Rated voltage

240 .. 600V

Adjustment range short-term delayed short-circuit release

25 .. 250A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

25 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

35kA

With under voltage release

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.